RESTRICTED OR BLOCKED AIRFLOW
Check the duct condition.
If the VENT LED is blinking, check the exhaust system
for restrictions and damage. Repair or replace the
exhaust system as needed.
NOTE: When the dryer is rst installed, this test
should be performed to alert you to any existing
problems with the exhaust ducts in your home.
However, since the test performed during normal
operation provides more accurate information on
the condition of the exhaust duct than does the
installation test, the results of the two tests may not be
the same.
Do not interrupt the test cycle, as this could result in
inaccurate results.
Even if the LED is not blinking during the test cycle,
some restrictions may still be present in the exhaust
system. Refer to the Venting the Dryer section of
this guide for complete exhaust system and venting
requirements.
Avoid long runs or runs with multiple elbows or bends.
Excess or crushed
transition duct
Check for blockages and lint buildup.
Too many elbows or
exhaust too long
Lint
blockage
buildup or
Make sure the ductwork is not crushed or restricted.
Crushed
or
damaged
exhaust