Loading ...
Loading ...
Loading ...
English18
Installation instructions
Installation instructions
Meeting Electrical Codes
The owner shall verify that all electrical requirements are met by the qualified
electrician servicing this appliance.
The electrical installation (incl. minimum supply-wire size and grounding) must comply
with the National Electric code ANSI/NFPA (or latest revision), and local codes. Obtain a
copy of the ANSI/NFPA standard from:
- National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The ground terminal on the hood must be connected to a grounded, metallic,
permanent wiring system, or a grounding conductor installed by a licensed electrician.
Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral
(white) power supply wire.
Do not install a fuse in the neutral or ground circuit.
Connect the hood directly to an electrical junction box. Hard-wire the hood per local
code directly to a dedicated, three-wire-grounded, single-phase circuit rated at 120 Vac
60 Hz, 15 Amp.
WARNING
Electrical Shock Hazard
Ensure a licensed electrician installs the electrical service to the range hood.
Loading ...
Loading ...
Loading ...