PROBLEM SOLUTION
Indoor unit display
indicates
, , "
•Thisisnotadefect.Iftheairconditionerreceivesa
DemandResponsesignalfromthepowersupply
utility,thenthecompressorandfanswillbeoperated
accordingtoDRMmode(DRM1,2,3).Theindoorunit
displaywillindicate"
, , ".
Operation ranges
Thetablebelowindicatesthetemperatureandhumidityrangestheairconditioner
canbeoperatedwithin.Refertothetableforecientuse.
MODE
OPERATIONAL TEMPERATURE
INDOOR
HUMIDITY
IF OUT OF CONDITIONS
INDOOR
OUTDOOR
NS

HHXEG AC

JNHFKH
COOLING 18˚Cto32˚C -15˚Cto46˚C -15˚Cto50˚C 80%orless
Condensationmayoccuronthe
indoorunitwithrisktohaveeither
waterblowoordropsontheoor.
HEATING 27˚Corless -20˚Cto24˚C -20˚Cto24˚C -
Internalprotectiontriggersandthe
airconditionerwillstop.
DRYING 18˚Cto32˚C -15˚Cto46˚C -15˚Cto50˚C -
Condensationmayoccuronthe
indoorunitwithrisktohaveeither
waterblowoordropsontheoor.
• Thestandardizedtemperatureforheatingis7˚C.Iftheoutdoortemperaturedropsto0˚Corbelow,the
heatingcapacitycanbereduceddependingonthetemperaturecondition.Ifthecoolingoperationis
usedatover32˚C(indoortemperature),itdoesnotcoolatitsfullcapacity.
NOTE
•
Theuseoftheairconditioneratarelativehumidityabovetheexpectedone(80%)may
causetheformationofcondensateandtheleakageofwaterdropsontheoor.
CAUTION