Using your air conditioner
DEMAND RESPONSE MODE (DRM 1, 2, 3)
This air conditioner is equipped with a Demand Response unit which will respond to a signal sent by the power
supply utility during emergency conditions.
During a Demand Response Event, the indoor and outdoor unit will be operated according to DRM mode(DRM
1, 2, 3) and indoor unit will show "
, , " on the display.
Away/MDS
AIR CONDITIONER DEMAND RESPONSE MODES
Operational
instruction
(OI)
Demand
response mode
(DRM)*
Description of operation in this mode
Mandatory for compliance
with this Standard (AS/NZS
4755.3.1)
OI 1 DRM 1 Compressor o Yes
OI 2 DRM 2
The air conditioner continues to cool or heat
during the demand response event, but the
electrical energy consumed by the air conditioner
in a half hour period is not more than 50% of the
total electrical energy that would be consumed
if operating at the rated capacity in a half hour
period.
No
OI 3 DRM 3
The air conditioner continues to cool or heat
during the demand response event, but the
electrical energy consumed by the air conditioner
in a half hour period is not more than 75% of the
total electrical energy that would be consumed
if operating at the rated capacity in a half hour
period.
No