99
Metering
5
Advanced shooting
Turning the camera off or changing the shooting mode will return
the metering target to the center position.
Multi-metering
– Metering the exposure at more than one point
1 Turn the control dial while holding
down 4 and select MULTI3.
•MULTI 3 is displayed on the control
panel.
2 Position the AF target mark on the
area you want to meter and press
the AEL (AE Lock) button. The
brightness is metered at up to 8
different points.
The multi-metering bar appears on the
monitor.
Brightness meter readings are ignored after the 8th reading.
To perform metering again, press the AEL button for more than 1
second to display C. Press the AEL button again to cancel the
metering values.