Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 35
DETERGENT MODE – This funcon is used to congure the way the EcoFlex system behaves or to disable it. Dierent
geographic locaons desire dierent EcoFlex behavior. This mode provides the ability to match the behavior to market
area desires.
• OFF – Disables EcoFlex feature
• MODE 1 – Expected to be used in combinaon with N.AMERICA CHEM MODE.
• MODE 2 – Expected to be used alone or in combinaon with GLOBAL CHEM MODE.
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
BATTERY CHARGER SELECTION –This funcon is used to inform the Main Machine Controller whether or not the ma-
chine is equipped with the oponal S.P.E. on-board baery charger (The S.P.E charger was used on early machines. Later
machines use the Delta-Q IC650 baery charger). It is also used to inform the controller of what kind of baeries the
machine is equipped with. The Main Machine Controller will request a specic charging prole from the S.P.E baery
charger to match the baeries.
• NONE (Use when not equipped with on-board baery charger)
• WET 25A (Use with 242 AH WET Baeries 56206079 or 310 AH WET Baeries 56391391)
• AGM DISCOVER 25A (Use with 312 AH AGM Baeries 56315959)
• GEL EXIDE 25A
• GEL-AGM 25A
• WET 15A
• GEL-AGM 15A
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
LOW VOLT CUTOUT - The purpose of the low baery voltage cutout funcon is to help prolong baery life. The scrub
deck will be raised and the brush motors, vacuum motor, and soluon solenoid valve will turn OFF automacally and
cease to funcon when the baeries discharge to the selected cutout level. The cutout level is adjustable between two
sengs. The standard seng (wet cell/lead acid) is 20.55 volts and alternate seng (AGM) is 21.75 volts.
• WET BATTERY 80%, LVC = 20.55V
• MAIN FREE BATTERY 70%, LVC = 21.75V
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.