DETERGENT MODE – This funcon is used to congure the way the EcoFlex system behaves or to disable it. Dierent
geographic locaons desire dierent EcoFlex behavior. This mode provides the ability to match the behavior to market
area desires.
• OFF – Disables EcoFlex feature
• MODE 1 – Expected to be used in combinaon with N.AMERICA CHEM MODE.
• MODE 2 – Expected to be used alone or in combinaon with GLOBAL CHEM MODE.
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
BATTERY CHARGER SELECTION –This funcon is used to inform the Main Machine Controller whether or not the ma-
chine is equipped with the oponal S.P.E. on-board baery charger (The S.P.E charger was used on early machines. Later
machines use the Delta-Q IC650 baery charger). It is also used to inform the controller of what kind of baeries the
machine is equipped with. The Main Machine Controller will request a specic charging prole from the S.P.E baery
charger to match the baeries.
• NONE (Use when not equipped with on-board baery charger)
• WET 25A (Use with 242 AH WET Baeries 56206079 or 310 AH WET Baeries 56391391)
• AGM DISCOVER 25A (Use with 312 AH AGM Baeries 56315959)
• GEL EXIDE 25A
• GEL-AGM 25A
• WET 15A
• GEL-AGM 15A
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.
LOW VOLT CUTOUT - The purpose of the low baery voltage cutout funcon is to help prolong baery life. The scrub
deck will be raised and the brush motors, vacuum motor, and soluon solenoid valve will turn OFF automacally and
cease to funcon when the baeries discharge to the selected cutout level. The cutout level is adjustable between two
sengs. The standard seng (wet cell/lead acid) is 20.55 volts and alternate seng (AGM) is 21.75 volts.
• WET BATTERY 80%, LVC = 20.55V
• MAIN FREE BATTERY 70%, LVC = 21.75V
To change the seng:
1. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired value.
2. To save and go back to the main menu, press the scrub ON/OFF switch.