Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 151
Trip Type Type Description Trip Code Code Description and Possible Causes
5 Not Used
6 Inhibit Active 0A00 Sleep Mode.
This occurs when the controller enters Sleep Mode. Turn the
controller off and then on to awake the system. To disable
Sleep Mode, program the parameter Sleep Timer to 0 min-
utes.
6 Inhibit Active 1E08* Inhibit 1 Active.
This occurs when the controller detects that the Inhibit 1 in-
put is active, Inhibit 1 Speed has been set to ‘0’ and Inhibit 1
Operation has been set to ‘Latched’. This input is located on
pin 6 of the 14-way Tiller Connector. Check the state of the
input, Inhibit 1 programming, connectors and relevant wiring
to the i-Drive.
If the trip is still present after the state of the input, program-
ming, connectors and wiring have been checked, the control-
ler may be defective. Refer to Section 3.
6 Inhibit Active 1E09* Inhibit 2 Active.
This occurs when the controller detects that the Inhibit 2 in-
put is active, Inhibit 2 Speed has been set to ‘0’ and Inhibit 2
Operation has been set to ‘Latched’. This input is located on
pin 14 of the 14-way Tiller Connector. Check the state of the
input, Inhibit 2 programming, connectors and relevant wiring
to the i-Drive.
If the trip is still present after the state of the input, program-
ming, connectors and wiring have been checked, the control-
ler may be defective. Refer to Section 3.
7 Throttle Trip 0815 Throttle Trip.
This occurs when the controller detects an error with one of
the throttle references, either high or low. The throttle refer-
ences are located on pins 2 and 8 of the 14-way Tiller Con-
nector, respectively. Check the throttle potentiometer, con-
nectors and relevant wiring to the i-Drive.
If the trip is still present after the potentiometer, connectors
and wiring have been checked, the controller may be defec-
tive. Refer to Section 3.