Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 128
Brush Head Actuator
1. Empty recovery tank.
2. Press the scrub buon to lower the brush head.
a. If the actuator does not move, slightly raise the brush head with a jack to take tension o of the mount-
ing hardware.
3. Tip the recovery tank up.
4. Disconnect electrical connector so the actuator will not move and then turn the key o.
5. Remove upper and lower fasteners.
6. Remove actuator.
7. Reassemble in reverse order.
8. Tighten the upper actuator nut and bolt unl it is snug and then back o approximately 1/2 turn. This joint must
be allowed to move freely.
Lower Fastener
Upper Fastener