18
* If a second degauss cycle is needed, allow a minimum interval of 20 minutes for the best result. A humming noise may be heard, but this is not a
malfunction.
Displaying this monitor’s name, serial number,
and date of manufacture.
While the monitor is receiving a video signal, press and hold the
joystick for more than 5 seconds to display this monitor’s
information box.
Wavy or elliptical pattern (moire)
is visible
Set CANCEL MOIRE to ON and adjust the degree of moire cancellation until the moire is
at a minimum (page 13).
x
Problems caused by the connected computer or other equipment
Change your desktop pattern.
Color is not uniform
Degauss the monitor* (page 14). If you place equipment that generates a magnetic field,
such as a speaker, near the monitor, or if you change the direction the monitor faces, color
may lose uniformity.
Adjust the landing (page 13).
White does not look white
Adjust the color temperature (page 11).
Check that the five BNC connectors are connected in the correct order (page 6).
Letters and lines show red or blue
shadows at the edges
Adjust the convergence (page 14).
Monitor buttons do not operate
( appears on the screen)
If the control lock is set to ON, set it to OFF (page 14).
IMAGE RESTORATION function
does not operate
Before using this function, the monitor must be in normal operation mode (green power
indicator on) for at least 30 minutes. For more information on using the IMAGE
RESTORATION function, see page 13.
Adjust the computer’s power saving settings to keep the monitor in normal operation
mode for more than 30 minutes.
The monitor may gradually lose its ability to perform this function due to the natural aging
of the picture tube.
USB peripherals do not function
Check that the appropriate USB connectors are securely connected (page 7).
Check that the ! (power) switch is in the “on” position.
x
Problems caused by the connected computer or other equipment
Check that the power of any self-powered USB compliant peripheral devices is “on.”
Install the latest version of the device driver on your computer. Contact your device’s
manufacturer for information about the appropriate device driver.
If your USB compliant keyboard or mouse does not function, connect them directly to
your computer, reboot your computer, and make any necessary adjustments to the USB
settings. Then reconnect the keyboard or mouse to the monitor. If you connect a keyboard
or mouse to the USB connectors and then boot your computer for the first time, the
peripheral devices may not function.
A hum is heard right after the
power is turned on
This is the normal sound of the auto-degauss cycle. When the power is turned on, the
monitor is automatically degaussed for 3 seconds.
Symptom Check these items
EASY EXPERT s BGR
5000K 6500K 930 K0
50 K00
IMAGE
RESTORATION
AVAI LABLE
AFTER WARM UP
COLOR
SER NO
:
1234567
MODEL
:
GDM FW9011
MANUFACTURED
: 2000-52
INFORMATION
Example
b
Loading ...
Loading ...