51
WARRANTY
Problem Cause Solution
Vent is not working
Weak or no ventilation
Abnormal noise during
operation
Product overheating
1. Improper blower unit direction or installation
2. Improper ductwork or damper connection
1. Check blower unit direction
and reinstall if necessary.
2. Properly align the exhaust
ports and blower plate
opening.
Slide exhaust
adapter into
guides on
rear panel.
Exhaust Adapter
Damper
(hinge side up)
Locking
Tabs
Guides
3. Blower unit exhaust ports
should be completely exposed
to the outside
4. After installation, check the air
ventilation path
The cost of repair or replacement under these excluded circumstances shall be borne by the consumer.