59
6.1.4 Media Sensor Calibration (for the Black Mark Sensor)
1. Turn off the printer.
2. Press and hold the right Selection button, and then turn on the Power Switch.
3. Release the button when Bline Calibration appears on the screen.
Note
The LED color will change as follows:
Amber (lit) red (5 times) amber (5 times) green (5 times) green/amber (5 times)
red/amber (5 times) green (lit)
6.1.5 Media Sensor Calibration (for the Gap Sensor)
1. Turn off the printer.
2. Press and hold the right Selection button, and then turn on the Power Switch.
3. Release the button when Gap Calibration appears on the screen.
Note
The LED color will change as follows:
Amber (lit) red (5 times) amber (5 times) green (5 times) green/amber (5 times)
red/amber (5 times) green (lit)