STEPS FOR TROUBLESHOOTING THE LMWEKITU
Compatible Operators
LMWEKITU DIAGNOSTIC CODES
84
1
Non-monitored device detected on the
wireless safety system
Ensure that the installed edge is a Liftmaster product. Perform step 5.
68 Wireless Edge triggered Normal response when an edge makes contact with an object. If it is constant, perform step 5.
69 Wireless Edge loss of monitoring Check the testing steps below, paying attention to intermittent wire connections.
Check the advanced diagnostic codes
2
for further diagnostic information.
1
Available in firmware 4.2 or higher.
2
Available in firmware versions 3.5 and higher.
ÉTAPES DE DÉPANNAGE DU LMWEKITU
Actionneurs compatibles
CODES DE DIAGNOSTIC DU LMWEKITU
84
1
Dispositif non surveillé détecté sur le système
de sécurité sans fil
S’assurer que la bordure de détection installée est un produit LiftMaster. Effectuer l’étape 5.
68 Bordure sans fil déclenchée Réponse normale quand la bordure entre en contact avec un objet. Si le déclenchement est constant, effectuer l’étape 5.
69 Perte de surveillance de la bordure sans fil Vérifier les étapes de mises à l’essai ci-dessous en portant attention aux connexions de fil intermittentes.
Vérifier les codes de diagnostic avancé
2
pour plus d’information à ce sujet.
1
Offert dans le micrologiciel de version 4.2 ou plus.
2
Offert dans les versions logicielles 3.5 et plus.
.
PASOS PARA RESOLVER PROBLEMAS DEL LMWEKITU
Operadores compatibles
CÓDIGOS DE DIAGNÓSTICO DEL LMWEKITU
84
1
Se detectó un dispositivo no monitoreado en
el sistema de seguridad inalámbrico
Asegúrese de que el borde instalado sea un producto LiftMaster. Realice el Paso 5.
68 Borde inalámbrico activado Respuesta normal cuando un borde hace contacto con un objeto. Si es constante, realice el paso 5.
69 Pérdida de monitoreo del borde inalámbrico Verifique los siguientes pasos de prueba, prestando atención a las conexiones de cables intermitentes.
Para obtener más información de diagnóstico, consulte los códigos de diagnóstico avanzados
2
.
1
Disponible en la versión de firmware 4.2 o superiores.
2
Disponible en las versiones de firmware 3.5 y superiores.
DETAILED STEP BY STEP TESTING THE LMWEKITU
1. Bypass the I2C Interface board and/or the expansion board. This provides a good means for troubleshooting by the process of elimination.
a. Make sure that the receiver is plugged into the main board.
i. If the receiver is plugged into the I2C interface board or into a two position plug on the expansion board, remove
the harness between the main board and the I2C interface board (or expansion board).
ii. Move the receiver harness from the other I2C interface board jack and plug it into the main board jack freed up by step i.
2. Activate the edge(s).
a. On the edge’s transmitter, the red LED should flash when the edge is pressed, and then again when it is released.
i. If the LED in the transmitter doesn’t flash:
1. Check the batteries.
2. Perform the steps outlined in Step 5.
b. On the receiver, the red LED should flash when the edge is pressed, and then it will flash about five seconds after
the edge is released.
i. If the LEDs in the receiver doesn’t flash:
1. Perform the steps outlined in Step 6.
2. Perform the steps outlined in Step 7.
3. Perform the steps outlined in Step 8.
c. On the logic board, either the close edge or the open edge (depending upon the switch setting of the transmitter).
will flash when the edge is squeezed, until about 5 seconds after the edge is released.
d. Repeat the tests for all edges.
3. Replace the I2C Interface board (if applicable).
a. Plug the receiver into the I2C interface board.
i. Move the receiver plug from the main board back to the free jack on the I2C
interface board.
ii. Remove all accessories including LOOPDETLM detectors from the expansion board.
iii. Check to see that the power LED is flashing once a second. If it is not flashing:
1. Check the harness for correct insertion into the I2C interface board.
2. Ensure that the I2C interface board is properly installed onto the expansion board pin
for pin.
3. Check to verify that the LED flashes without the I2C expansion board installed
iv. Perform Step 2. If it doesn’t work consider replacing
1. Expansion board
2. Expansion board harness
v. Replace the loop detectors (LOOPDETLM) one at a time, performing Step 2 after each
detector. If it stops working, exchange or replace the detector
vi. Add one accessory at a time, performing step 2) after each accessory. If it stops working,
exchange or replace the accessory.
b. I2C Interface board is not used on those operators that don’t have an expansion board
installed.
c. Some expansion boards have an integrated second I2C connector. There is no need to install
the I2C Interface boards on these operators.
Control Board
Carte logique
Tarjeta de control
Expansion Board
Carte d’extension
Tablero de expansión
6-19 x 1" (for plastic)
6-19 x 1 po (pour le plastique)
6-19 x 1 pulg. (para plástico)
6-32 x 1" (for metal)
6-32 x 1 po (pour le métal)
6-32 x 1 pulg. (para metal)
To Main Control Board
À la carte mère
Al tablero de
control principal
I2C Interface Board
Carte
d’interface I2C
Tablero de
interfaz I2C
OR
OU
O
If needed
Au besoin
Si fuera necesario
• CSW24U
• CSL24U
• LA500U
• LA400U
• LA412U
• CSW200U
• RSW12U
• RSL12U
• SL3000U
• SL585U
• SL595U
• CSW24UL
• CSL24UL
• LA500UL
• LA400UL
• LA412UL
• CSW200UL
• RSW12UL
• RSL12UL
• SL3000UL
• SL585UL
• SL595UL
• CSW24U
• CSL24U
• LA500U
• LA400U
• LA412U
• CSW200U
• RSW12U
• RSL12U
• SL3000U
• SL585U
• SL595U
• CSW24UL
• CSL24UL
• LA500UL
• LA400UL
• LA412UL
• CSW200UL
• RSW12UL
• RSL12UL
• SL3000UL
• SL585UL
• SL595UL
• CSW24U
• CSL24U
• LA500U
• LA400U
• LA412U
• CSW200U
• RSW12U
• RSL12U
• SL3000U
• SL585U
• SL595U
• CSW24UL
• CSL24UL
• LA500UL
• LA400UL
• LA412UL
• CSW200UL
• RSW12UL
• RSL12UL
• SL3000UL
• SL585UL
• SL595UL
Loading ...
Loading ...
Loading ...