INSTALLATION INSTRUCTIONS
EN
7
Electrical connection
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
This downdraft unit may only be used in connection with Fisher & Paykel internal or
remote blowers.
Unplug or disconnect the appliance from the power supply before servicing or cleaning.
Electrical requirements
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp circuit,
fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
The fuse must be sized per local codes in accordance with the electrical rating of this
downdraft unit as specified on the serial/rating plate located inside the downdraft unit
near the field wiring compartment.
This downdraft unit must be connected with copper wire only. Wire sizes must conform
to the requirements of the National Electrical Code, ANSI/NFPA 70 -latest edition, and all
local codes and ordinances. Wire size and connections must conform with the rating of
the appliance. Copies of the standard listed above can be obtained from:
National Fire Protection Association
Battery March Park
Quincy, Massachusetts 02269
This appliance should be connected directly to the fuse disconnect (or circuit breaker)
through flexible, armored or non-metallic sheathed copper cable. Allow some slack
in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed
strain relief or ½”(12.7mm) conduit connector must be provided at each end of the
power supply cable (at the appliance and at the junction box).
When making the electrical connection, cut a 1¼” (32mm) hole in the wall. A hole cut
through wood must be sanded until smooth. A hole through metal must have a grommet.
Note: suitable for use with solid state speed controls.