16
INSTALLATION INSTRUCTIONS
3
Temporarily insert the downdraft into the cabinet
With the assistance of another person, lift the downdraft unit into the prepared cutout
in the cabinet. The over counter mounting brackets should rest on the countertop.
Secure the downdraft unit to the countertop with two ⁄” (15mm) screws.
Install the under counter mounting brackets underneath the countertop for additional
support. First, loosely screw the brackets into the sliding nuts in the downdraft
unit using ⁄” (5mm) screws and push them up under the countertop. Pre-drill
the mounting holes into the countertop from underneath. Check that the mounting
screws are the proper length and will not extend through the countertop surface
when tightened. Failure to follow these instructions could result in damage to the
countertop surface Fig.5.
Level and align the downdraft unit in the cabinet. Push the support leg mounting
bracket on each side down against the cabinet floor. Mark the top edge of the
mounting bracket on the downdraft unit and the mounting holes on the cabinet
floorFig.6.
4
Remove the downdraft from the cabinet
Remove the screws from the countertop and lift the downdraft unit back out of
thecabinet.
Pre-drill the marked mounting holes in the cabinet floor.
Tighten the support leg mounting brackets on the unit at the pre-marked positions
Place the downdraft unit on a flat protected surface to prevent damage in order to
install the blower.
5
Install the internal or remote blower
For internal blower installation refer to page 17.
For remote blower installation refer to page 18.
Note: this downdraft unit may only be used in connection with Fisher & Paykel
internal or remoteblowers.
2 x
2 x
Fig.5 Fig.6
Loading ...