INSTALLATION INSTRUCTIONS
6
Prepare for electrical connection
Downdraft unit
Remove the cover of the terminal box from the downdraft unit Fig.14.
Decide whether the power source should enter the downdraft unit from below or
from the back and remove the respective knock out. Install a UL listed strain relief or
conduit fitting (not included) in the knock out Fig.15.
If the downdraft unit is being installed with a remote blower, remove the knock out
for the control cable.
With the assistance of another person, lift the downdraft unit into the prepared cutout
in the cabinet. The over counter mounting brackets should rest on the countertop.
Secure the downdraft unit to the floor and countertop with screws into the previously
drilled holes Fig.16.
Push the end caps into place on the downdraft unit on top of the counter and lock
them in place Fig.17.