Nilfisk SC750 Heavy-Duty Cleaning

User Manual - Page 33

For SC750.

PDF File Manual, 164 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 33
Soware Revision Code – This funcon is used to display the soware revision. The Fault LED blinks a two-part code to
indicate the revision of the soware that is currently programmed into the microcontroller program memory. The rst
part of the code indicates the released revision leer: 1 blink = revision A, 2 blinks = revision B, etc.
To check the revision:
1. While pressing and holding the vacuum and scrub switches forward, turn the key switch
on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The Low, Medium and High Soluon Flow indicators will remain on and the fault indicator will ash out the revision code.
Programming Options – SC750 and SC800 models (Control Panel with membrane switches)
Main Machine Controller special program opons allow the service repairperson to match the control board to the spe-
cic model equipment and to user preferences. They also allow adjustments to some machine funcons, and provide a
way to see the controllers revision level. On SC750 and SC800 models, all program opon modes are entered through a
“hidden menu” that is displayed on the LCD.
To enter the Programming Opons mode: (Start with the baery charger unplugged and the key o)
1. Press and hold the scrub ON/OFF switch and Vacuum/Wand switch together.
2. While holding both switches, turn the Key Switch to the ON posion.
3. Connue to hold both switches about 3 seconds unl the
display shows “Programming Opons”, then release the
switches.
4. Scroll through the menu using the Soluon Increase and Decrease switches unl you get to the desired program-
ming opon.
5. Press the Soluon On/O switch to enter the mode.