Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 112
Brush Head Actuator
1. Empty recovery tank.
2. Press the scrub buon to lower the brush head.
a. If the actuator does not move, slightly raise the brush head with a jack to take tension o of the mount-
ing hardware.
3. Li recovery tank up.
4. Disconnect electrical connector so the actuator will not move and then turn the key o.
5. Remove upper and lower fasteners.
6. Remove actuator.
7. Reassemble in reverse order.