Combined Single Stage Heat Pump and Single
Stage Furnace (Dual Fuel)
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, W1 and G wires from the Furnace to R/RC, C,
W/E/AUX and G terminals on the wall plate, respectively
Connect the C, Y1, G, and O/B wires from the Heat Pump to
C, Y, G, and O/B/W2 terminals on the wall plate, respectively
Humidifier or Dehumidifier Accessory
with a Single Stage Heat Pump
Note: The wiring configuration for humidifiers and dehumidifiers is the
same for all type of Heat Pump Systems
Ensure that the accessory is externally powered
Ensure the Heat Pump System is wired correctly
Connect the control wire of the accessory to the H/DH
terminal of the wall plate
Wiring Diagrams