Karcher HBG-30D Wastewater Evaporator 11034490

User Manual - Page 47

For 11034490.

PDF File Manual, 50 pages, Read Online | Download pdf file

11034490 photo
Loading ...
Loading ...
Loading ...
HBG EVAPORATOR OPERATOR’S MANUAL
47
HBG • 8.913-990.0-K
ETL Certifi ed
SPECIFICATIONS
HBG COST FORMULAS
Propane conversion from gallons of propane to therms for use in chart below: 1 Therm = 1.0929 gallons of propane.
Multiply the cost of 1 gallon of propane by 1.0929 to determine the propane cost per therm.
Example: Propane = $1.50 gallon. Multiply 1.0929 (gallons of propane per therm) x $1.50 (cost of gallon of
propane)= $1.6393 per therm.
Constants:
1 cubic foot of natural gas = 1,000 BTU's 1 gallon of propane = 91,500 BTU's
1 gallon of propane = 0.915 therms 1 therm = 100 standard cubic feet of natural gas
1 therm = 100,000 BTU's
Operating Cost for Natural Gas:
Gas Cost (Cost per Gallon) = HBG Rating BTU's per Hour x Local Cost of Fuel per Therm
BTU's per Therm x HBG Evaporation Rate
Operating Cost for Electricity:
Electricity Cost (Cost per Gal) = Volts x Amps x Cost of Kilowatt Hour
1000 x HBG Evaporation Rate
Example for HBG-15: 180,000 BTU/Hr, 40¢/Therm, 120 Volts, 3 Amps, 6¢/KWH
Gas Cost (¢/Gal) = 180,000 x 40 = 5.5 ¢/Gal
100,000 x 13
Electricity Cost (¢/Gal) = 120 x 3 x 6 = .1¢/Gal
1000 x 13
Total Cost = 6.2¢ (gas) + .1¢ (elec) = 6.3¢/Gal
MODEL FUEL USAGE EVAPORATION RATE
HBG-15 180,000 BTU / HR 13 gallons per hour
HBG-30 311,000 BTU / HR 28 gallons per hour
MODEL HBG-15 HBG-30
EVAPORATION RATE
10-15 GPH (38 - 57 Liter/Hr) 25-30 GPH (95 - 114 Liter/Hr)
ENERGY SOURCE
Natural Gas or LPG
ENERGY USAGE
180,000 BTU/HR 311,000 BTU/HR
TANK CAPACITY
70 Gallons (265 Liters) 120 Gallons (379 Liters)
TANK MATERIAL MILD STEEL
“3/8”” Plate Floor, 3/16”” Gauge Walls”
STAINLESS STEEL
“1/4”” Plate Floor, 12 Gauge Walls”
INSULATION
Air Insulated
WEIGHT
1,215 Lbs. (552 Kg) 1,485 Lbs. (675 Kg)
DIMENSIONS W x L x H
33" x 78.5" x 65"
(84 x 199 x 165 Cm)
90" x 44" x 70"
(229 x 112 x 178 Cm)
POWER REQUIREMENTS
120V, 1 PH, 3 Amps (13 amps for electric autofi ll)
WARRANTY
1 Year Parts 1 Year Parts
Note: NG calculations
Loading ...
Loading ...
Loading ...