©2017 Pinnacle Climate Technologies 14 Vented Gas Log Appliance Users Manual
Operation (cont.)
The replace screen must be in place when operating the appliance. Unless other
means for combustion are provided, the screen must have an opening or openings for
the adequate introduction of combustion air.
WARNING
Any glass doors must be completely opened when the appliance is operating.
WARNING
Care and Maintenance
Before servicing, turn o the appliance and let it cool.
WARNING
Keep the control areas, burner, and circulating air passageways of the appliance clean.
Carefully inspect these areas before each use. Have the appliance inspected yearly by a
qualied service person. Depending on your environment, the appliance may need more frequent cleaning
as a result of excessive lint from carpeting, pet hair, or other contaminants.
CAUTION
Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting
and property damage.
WARNING
This appliance requires curing the rst time it is operated. Complete the following
instructions for curing to avoid cracking the logs with continued use.
CAUTION
When the appliance is rst operated, it goes through a 3-hour curing period. During this time, the appliance
may emit an odor. This odor is temporary and indicates that the various compounds and paints used in the
appliance are curing. This is normal and expected. However, you may wish to provide the room with extra
ventilation during this period to help combat the odor.
Perform the following to properly cure the logs:
1. Ignite a 2" ame. Maintain the ame for one (1) hour.
2. Let the logs cool down for 30 minutes.
3. Ignite the appliance again but with the ame 2" higher than the last time. Maintain the ame for one (1) hour.
4. Repeat steps 2–3 until the ame reaches its maximum height, burning for a total of three (3) hours.
Do not burn solid fuels in the replace when the appliance is operating.
WARNING