User Manual Dimplex CFH120 12kW Commercial Fan Heater

Dimplex CFH120 12kW Commercial Fan Heater - Use Manual - Use Guide PDF.
Documents: Go to donwload!
User Manual
  • Owner's manual - (English, French, German, Dutch - Holland, Italian, Polish)
  • CFH Instructions Issue 1 - (English)
Other Documents
  • Commercial Brochure - (English)
  • CFH Flyer 2013 - (English)
  • CFH FAQs - (English)
  • CFH Spec Sheet - (English)
  • CFH120%20 %20cfh120 series e parts list - (English)
  • CFH120%20 %20cfh120 series f parts list - (English)
  • CFH120%20 %20cfh120 series j parts list - (English)
  • CFH120%20 %20cfh120 series g parts list - (English)
  • CFH120%20 %20cfh120 series k parts list - (English)
  • CFH120%20 %20cfh120 series h parts list - (English)
  • CFH120%20 %20cfh120 series l parts list - (English)
  • CFH120%20 %20cfh120 series i parts list - (English)
  • CFH120%20 %20cfh wiring diag - (English)
  • CFH120%20 %20cfh120 wiring diag issue 003 - (English)
  • CFH120%20 %20cfh120 wiring diag issue 004 - (English)

file thumbnail

User manual Electronic Wall Mounted Fan Heater Dimplex CFH120

Delayed Shutdown

Door Switch (3min Runback)

  • Up to 1 minute after contact closed, unit runs at set condition.
  • Between 1 & 2 minutes. unit runs half & half settings.
  • Between 2 & 3 minutes. unit runs fan only settings.
  • Over 3 minutes. unit enters stand-by mode.

PIR Sensor (45min Runback)

  • Up to 15 minutes after contact closed, unit runs at set condition.
  • Between 15 & 30 minutes. unit runs half & half settings.
  • Between 30 & 45 minutes. unit runs fan only settings.
  • Over 45 minutes. unit enters stand-by mode.

Thermal Safety Cut-out

  1. Air inlet or outlet grilles are obstructed.
  2. Internal ventilation is impaired due to build up of dust and fl uff.
  3. Blower unit stalls.

Maintenance

  • WARNING: Disconnect electrical supply to all connected units prior to carrying out maintenance.
  • Optimum performance and long service from this product will only be realised if regular maintenance is carried out. Dimplex recommends regular checks dependant on normal use or more frequent checks where the unit is installed in arduous conditions or used continually for more than 10 hours per day.

Standard Maintenance

  • Where the product is subject to use not exceeding 10 hours per day: Every 3 months the fan wheels, impellors, heating elements, air inlet and outlet grilles should be cleaned, removing dust and debris with a suitable soft brush.
  • Every 12 months all moving parts should be checked for free running with appropriate remedy/adjustment made where necessary

Extended Maintenance

  • Where the product is subject to arduous conditions or is used continually for more than 10 hours per day: Each month the fan wheels, impellors, heating elements and air inlet and outlet grilles should be checked and cleaned, removing dust and debris with a suitable soft brush.
  • Every 6 months all moving parts should be checked for free running with appropriate remedy/adjustment made where necessary.

Cleaning

  • WARNING: DISCONNECT SUPPLY before carrying out mainten