Luxpower LXP HYBRID Tools

User Manual - Page 6

For LXP HYBRID 3-6K.

PDF File Manual, 22 pages, Read Online | Download pdf file

LXP HYBRID 3-6K photo
Loading ...
Loading ...
Loading ...
07
08
3.4 Connection
3.4.1 Connection Overview
The system connection diagram is as below:
Please prepare the breakers before connetion, breakers selection recommendation for both DC and AC
Connection Terminals and Interfaces Overview
Battery
Terminals
PV
Terminals
AC
Terminal
UPS
Terminal
Wi-Fi
Module
DC
Switch
Communication
Interfaces
3.4.2 PV Connection
6-8 mm
- Before connection the PV, please use the multi-meter to measure the PV array voltage to
verify if PV array is working normally, if not, please fix the PV array to normally working
states before connection
C a b l e D i a m e t e rCross-section Minimum Voltage
2
3 - 6 mm
2-2.6mm 600V
The PV connection of LXP hybrid inverter is the same to traditional on-grid solar inverter (string inverter).
Cable Requirement:
Step 1:Turn off or disconnect the PV switch (DC switch). Then keep this switch always open during
the connection.
Step 2:Assemble the PV connector
a) Strip 6~8mm insulation from the cable end.
- When your PV panel ambient temperature could possibly be lower than 0, then please
check the PV array voltage up ceiling and if you are not sure please ask your system or
panel provider for further assistance. As when temperature is extremely low the PV panel
voltage will increase by a certain percentage.
b) Assemble the cable ends to crimp contacts.
c) Lead the cable through the cable gland, then insert into the corresponding insulator until it snaps
into place, then tighten the cable gland.
When verified the PV connector is tightly, align the 2 half connector and mate them together by hands
until clickis felt or heard.
UPS Load
UPS
Hybrid
DC Breaker
selection(2 poles)
AC Breaker selection(2 poles)
UPS Breaker
selection(2 poles)
LXP 6K (MG) 100V/100A 50A/230Vac 50A/230Vac
LXP 3K/3.6K/4K (MG)
100V/100A
40A/230Vac 40A/230Vac
LXP 6K HB (MG)
LXP 4K HB (MG)
LXP 4.6K/5K (MG)
100V/100A
50A/230Vac 40A/230Vac
500V/50A 50A/230Vac 50A/230Vac
500V/50A 50A/230Vac 50A/230Vac
500V/50A 50A/230Vac 50A/230Vac
Type AC,>0.3A
Type AC,>0.3A
Type AC,>0.3A
Type AC,>0.3A
Type AC,>0.3A
Type AC,>0.3A
LXP 5K HB (MG)
AC Breaker with RCD
Loading ...
Loading ...
Loading ...