Shut off the valve at the gas cylinder or the regulator before moving the product.
Only use the gas regulator supplied with the product. The outlet pressure shall be according to the table in the
chapter “Specifications”.
The tubing or the flexible hose must be changed if it is cut or worn or kinked.
Use only the type of gas and the type of cylinder specified by the manufacturer.
For use outdoors or in amply ventilated areas. An amply ventilated area must have:
Walls on all sides, but no overhead cover.
An overhead cover and no more than 2 side walls. These side walls may be parallel, as in a breezeway, or at right
angles to each other.
The minimum of 30% of the surface area permanently open. The surface area is the sum of the walls surface.
A
B
C
D
Total surface area A+B+C+D 100 %
Wall surface area A+B+C max. 70 %
Open surface area D min. 30 %
Close the valve of the gas cylinder or regulator after use.
The use of this product in enclosed areas can be dangerous and is PROHIBITED.
Provide adequate clearances around air openings into the combustion chamber.
This product is a combustion appliance. All combustion appliances produce carbon monoxide (CO) during the
combustion process. This product is designed to produce extremely minute, non-hazardous amounts of CO if
used and maintained in accordance with all warnings and instructions. Do not block air flow into or out of the
product.
Never use inside the house, or other unventilated or enclosed areas.
This product consumes air (oxygen). Do not use in unventilated or enclosed areas to avoid endangering your life.
During set up, check all connections and fittings for leaks using soapy water. Never use a flame to check for leaks.
Use as a heating product only. Never alter in any way or use with any device.
This product contains small parts, which pose a choking hazard. Keep children away from small parts.
Gas Safety
This product is fueled by LPG. LPG is invisible, odorless, and flammable. An odorant is sometimes added to help
detect leaks which can be described as a “rotten egg” smell. The odorant can fade over time so leaking gas is not
always detectable by smell alone.
LPG is heavier than air and leaking LPG will sink to the lowest level possible. It can ignite by ignition sources
including matches, lighters, sparks or open flames of any kind many feet away from the original leak. Use only LPG
set up for vapor withdrawal.
Store or use LPG in compliance with local ordinances and codes or with ANS/NFPA 58. Turn off LPG when not in
use.
Keep all connections and fittings clean. Make sure the LPG cylinder valve outlet is clean.
Store the LPG cylinder outdoors in a well ventilated space out of reach of children. Never store the LPG cylinder
in an enclosed area (house, garage, etc.). If the product is to be stored indoors, disconnect the LPG cylinder for
outdoor storage.
Never store LPG near high heat, open flames, pilot lights, direct sunlight, other ignition sources or where
temperatures exceed 122°F.
LPG vapors are heavier than air and can accumulate in low places. If you smell gas, leave the area immediately.
Never install or remove the LPG cylinder while the product is lighted, near flames, pilot lights, or other ignition
sources, or while the product is hot to the touch.
Change the gas cylinder in an amply ventilated area, away from any ignition source (candles, cigarettes, other
flame producing appliances).