Loading ...
Loading ...
Loading ...
19
Information on Gas Cylinders
Use this product only with a LPG vapor withdrawal supply system.
Storage of the product indoors is permissible only if the cylinder is disconnected and removed from the product.
A cylinder must be stored outdoors in a well-ventilated area out of the reach of children. A disconnected cylinder
must have dust caps tightly installed and must not be stored in a building, garage or any other enclosed area.
The pressure regulator and hose assembly supplied with the product must be used.
Check the hose and regulator before use.
Inspect the visible hose portion of the regulator before use. Check it completely at least annually.
Replacements of the hose and regulator must be those specified by the manufacturer.
The hose and regulator must be UL/CSA certified, the outlet pressure of the regulator must be according to the
table in the “Specifications” chapter. Suitable spare parts are available from specialist dealers.
The installation must conform with local codes.
A dented, rusted or damaged LPG cylinder may be hazardous and should be checked by your LPG supplier.
Never use a LPG cylinder with a damaged valve connection.
The length of the hose cannot exceed 4.6 ft.
The cylinder must have a listed overfilling prevention device.
The cylinder must have a connection device compatible with the connection for the product.
The cylinder must include a collar to protect the cylinder valve.
Never connect an unregulated LPG cylinder to the product.
Do not store a spare LPG cylinder under or near this product.
Never fill the cylinder beyond 80 % full.
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap
on the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of
LPG.
Operation
Leak Check
WARNING
Risk of explosion!
Perform all leak tests outdoors.
Extinguish all open flames.
Never leak test when smoking.
Do not use the product until all connections have been leak tested and do not leak.
1. Make 2 – 3 fl oz of soapy water (1 part liquid dish washing detergent and 3 parts water).
2. Apply several drops of the soapy water where the hose attaches to the regulator.