3. Apply several drops of the soapy water where the regulator connects to the cylinder.
4. Make sure all valves are closed.
5. Open the cylinder valve.
If bubbles appear at any connection, there is a leak.
1. Turn the cylinder valve off.
2. If the leak is at the hose/regulator connection, tighten the connection and perform another leak test. If bubbles
continue appearing, the hose/regulator connection should be replaced by a qualified service person.
3. If the leak is at the regulator/cylinder valve connection, disconnect, reconnect, and perform another leak check.
If you continue to see bubbles after several attempts, the cylinder valve is defective and should be replaced by a
qualified service person.
4. In the event of a gas leakage, the product shall not be used or, if alight, the supply shall be shut off and the product
shall be investigated and rectified before it is used again.
If no bubbles appear at any connection, the connections are secure.
NOTICE
Whenever gas connections are loosened or removed, you must perform a complete leak test.
5. Complete installation.
DANGER
Carbon monoxide hazard! For outdoor use only. Never use inside house, or other unventilated or
enclosed areas. This product consumes air (oxygen). Do not use in unventilated or enclosed areas
to avoid endangering your life.
CAUTION
Risk of injury! Do not attempt to operate until you have read and understand all general safety
information in this manual and all assembly is complete and leak checks have been performed.
Before turning the gas supply on:
1. Your product was designed and approved for outdoor use only. Do not use it inside a building, garage, or any
other enclosed area.
2. Make sure the surrounding area is free of combustible materials, gasoline, and other flammable vapors or liquids.
3. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks.
4. Be sure the cylinder cover is clear of debris. Be sure any component removed during assembly or servicing is
replaced and fastened prior to starting.
Before Lighting
1. The product should be thoroughly inspected before use, and by a qualified service person at least annually. If
relighting a hot product, always wait at least 5 minutes.
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should be leak
tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose assembly specified
by the manufacturer. The hose and regulator must be UL/CSA certified, the outlet pressure of the regulator must
be according to the table in the “Specifications” chapter.. Suitable spare parts are available from specialist dealers.
Lighting Instructions
1. Make sure the control knob is in the OFF position. Slowly open the LPG cylinder valve.
2. Press and turn the control knob to the PILOT position (counterclockwise). While holding the control knob in,
press the red piezoelectric ignition button several times in a row. You should hear a sparking or clicking sound of
the piezoelectric ignition. For the first ignition, hold the control knob down for 30 seconds to remove air from the
tube before pressing the red piezoelectric ignition button.
3. Continue to hold in the control knob and check for the pilot flame through the glass tube. If the pilot does not light,
press and turn the control knob clockwise to the OFF position. Repeat steps 2-3.