CONECTING THE POWER
2. For power cord installations only,hook the strain relief over the power cord hole located below the rear
of the drawer body.Insert the power cord through the strain relief and tighten the device.
You must install the power cord with a strain relief.
Attach the strain relief to the opening in conduit connection plate.
Step 3.4-wire power cord installation
WARNING
Electrical Shock Hazard
Electrical ground is required on this appliance. Do not connect to the electrical supply until appliance is
permanently grounded. Disconnect power to the circuit breaker or fuse box before making the electrical
connection.
This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding
connector should be connected to the grounding terminal or wire lead on the appliance. Failure to do any
of the above could result in a fire, personal injury or electrical shock. See below for more information on
electrical grounding.
A. Remove the 4 lower terminal screws from the terminal block.
B. Insert the 4 terminal screws through each power cord terminal and into the lower terminals of the
terminal block. Be certain that match the wire and terminals by color.
C. Tighten screws securely into the terminal block.
CAUTION
You must check voltage after connecting power cord.
Live 1-Neutral 120 V
Live 2-Neutral 120 V
Live 2-Live 2 208 V/240 V