FLUKE 1625-2 GEO Earth Ground Tester, -10 to 50°C

User Manual for the Fluke 1625-2 GEO Earth Ground Tester, -10 to 50°C - Page 45

For 1625-2.

PDF File Manual, 52 pages, Read Online | Download pdf file

1625-2 photo
Loading ...
Loading ...
Loading ...
1625-2
Users Manual
40
Table 8. Sample .CSV File for Logged Data (cont.)
Measurement
Interference
Frequency Fst
Interference
Current
Earthing
Impedance
55 Hz R*
Earth Ground
Resistance Re
AC Resistance
R~
DC Resistance
R1
1 0.0 Hz NA NA 1.022 Ω NA NA
2 0.0 Hz NA 1.02 Ω 1.022 Ω NA NA
3 100.0 Hz 0.0A 1.02 Ω 1.022 Ω NA NA
4 0.0 Hz 0.0A NA 1006 Ω NA NA
5 100.0 Hz NA NA NA 1.022 Ω NA
6 100.0 Hz NA NA NA NA 1.023 Ω
7 0.0 Hz NA NA NA NA NA
8 0.0 Hz 0.0A NA NA NA NA
Measurement
DC Resistance
R2
Probe
Resistance Rs
Auxilliary
Resistance Rh
Compensation
Resistance Rk
Transformer
Ratio I
Error Status
1 NA 0.1 kΩ 0.1 kΩ 0.025 Ω NA NA
2 NA 0.1 kΩ 0.1 kΩ NA NA NA
3 NA 0.1 kΩ 0.1 kΩ 0.075 Ω 1000 NA
4 NA 0.1 kΩ 0.5 kΩ NA 1000 NA
5 NA NA NA 0.025 Ω NA NA
6 1.022 Ω NA NA 0.025 Ω NA NA
7 NA NA NA NA NA E & H open
8 NA NA NA NA 1000
Reverse
clamp
Delete Stored Data
To delete stored data in the Tester:
1. Connect the USB cable from the Tester to the PC.
2. Use Windows Explorer on the PC to find new EGT drive in the Devices list.
3. Locate the Data.csv file on the EGT drive.
4. Use the standard PC tools to delete the file from the EGT drive or move the file to a
new location.
This action removes all stored date from the Tester.
1.888.610.7664 sales@GlobalTestSupply.com