FLUKE 1738/B Advanced Three-Phase Power Logger

User Manual for the Fluke 1738/B Advanced Three-Phase Power Logger - Page 37

For 1738/B.

PDF File Manual, 84 pages, Read Online | Download pdf file

1738/B photo
Loading ...
Loading ...
Loading ...
1736/1738
Users Manual
32
Auxiliary Input
The Logger supports up to two additional measurement channels with
either the wired AUX input or wireless radio signals from Fluke
Connect sensors.
Wireless Connection to Fluke Connect Modules
The Logger supports wireless radio communication with Fluke
3000-series modules to remotely monitor equipment. See Figure 6.
Wireless communication requires that the USB-1 FC WiFi-BLE
adapter is installed. See WiFi and WiFi/BLE-to-USB Adapter on
page 6 for more information.
To set up a module:
1.
Turn on the module.
2.
Push on the module to turn on the radio. The display shows
.
3.
On the Logger, select AUX 1 or AUX 2. Active FC sensors within
a 10 m range show in the selection list on the Logger. Highlight
the FC module and push
. The Logger assigns an ID number
to the module.
4.
Verify on the module:
ID number shows on the module
flashes to confirm the connection
Note
FC modules that are connected to another device are not
available and do not show in the selection list.
5.
Verify that the Measurement Configuration screen shows the ID
number and module type in the AUX field.
If the module moves out of range, the ID number does not
show in the Measurement Configuration screen to indicate that
the connection is broken. The connection is re-established when
the module moves back into range.
6.
On the Logger, go to the Meter screen to view the measurements
from the connected module.
Note
You cannot change the measurement parameter or unit on
the module during a logging session.
For more information about FC module support with the Logger, go to
w ww. . com
information@itm.com1.800.561.8187
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com
Loading ...
Loading ...