Hikvision DS-KD-AL8 Alarm In Module

User Manual - Page 47

For DS-KD-AL8.

PDF File Manual, 91 pages, Read Online | Download pdf file

DS-KD-AL8 photo
Loading ...
Loading ...
Loading ...
2.
Select I/O input No., input mode, output No., and output mode.
3.
Click Save to enable the sengs.
Note
For door staon, there are 4 I/O input terminals. By default, Terminal 1 and 2 correspond to
Door Status. Terminal 3 and 4 correspond to interfaces of Door Switch.
For door staon, there are 2 I/O Output Terminals. Terminal 1 and 2 correspond to Door
interfaces (NO1/COM/NC1; NO2/COM/NC2) of door staon. Door 1 is enabled by default. You
can enable/disable IO Out according to needs.
Sub Module Conguraon
Steps
1.
Click Intercom → Sub Module Conguraon , and you can view the sub module informaon,
including No., module type, status, and version.
2.
Click to edit the sub module.
Display Module
Slide to adjust Screen Backlight Brightness.
Slide Enable Buzzer to enable the funcon.
Touch-Display Module
Slide to adjust Screen Backlight Brightness.
Slide Enable Buzzer to enable the funcon.
Select Address Book Display Mode according to actual needs.
Enable Homepage Shortcut Dial, you can tap contact on the main page to call.
Click Add to add custom buons.
PMR Module
Click to enable power consumpon selecon.
You can select 8 W, 6 W or 4 W for the PMR Module.
Note
If the system power goes o, an external power supply of 12 V, 2 A for the main unit is
necessary.
Note
The module address is used to dierenate the sub modules. See Congure Sub Module
Address for detailed conguraon instrucons.
For the other sub modules (indicator module, keypad module and card reader module), it
prompts Not supported.
The room No. for the main unit's call buon is 1 by default; and the room No. for the nametag
modules call buons are 2 to 7 by default.
Module Door Staon User Manual