Hikvision DS-KD-AL8 Alarm In Module

User Manual - Page 46

For DS-KD-AL8.

PDF File Manual, 91 pages, Read Online | Download pdf file

DS-KD-AL8 photo
Loading ...
Loading ...
Loading ...
Call Sengs
Go to Intercom → Call Sengs to enter the page.
Congure Max. Call Communicaon, Max. Message Duraon and Max. Ring Duraon, and click
Save.
Note
Max. call duraon between the module indoor staon and client ranges from 90 s to 120 s. The
call will end automacally when the actual calling duraon is longer than the congured one.
Max. message duraon ranges from 30 s to 60 s. The message will end automacally when the
actual message duraon is longer than the congured one.
Max. ring duraon ranges from 65 s to 255 s.
Ring-Back Tone Sengs
Click Intercom → Ringbacktone Sengs to enter the sengs page.
Click Add to select the ring tone from PC.
Note
Available Audio Format: WAVAAC, Size: Less than 600 KB, Sample Rate: 8000Hz, Mono.
Press Buon to Call
Steps
1.
Click Intercom → Press Buon to Call to enter the page.
2.
Select Main Unit or Sub Module to set the buons.
Main Unit
If you select Main Unit, you should congure Buon Sengs and select Link Time Schedule
as Template Plan 1 or Enable Indoor Staon All Day by Default.
Sub Unit
When you select Sub Unit, all connected sub modules will be listed.
No. represents the address of each sub module.
Enter room No. of indoor staon in the Buon Sengs column for each alarm in interface.
3.
Click Save to enable the sengs.
I/O Sengs
Steps
1.
Click Intercom → I/O Sengs to enter the I/O input and output sengs page.
Module Door Staon User Manual
36