Thermal Network Bullet Camera User Manual
2
1.3 Main Functions
The main functions of this camera is fire source detection, and temperature measurement, and
VCA (video content analysis) functions.
Fire Detection
Fire Source Detection Shield enables you to shield certain areas from being detected in fire
source detection.
For fire detection, refer to Section 9.2.3 Configuring Dynamic Fire Source Detection.
Temperature Measurement
When you enable this function, it measures the actual temperature of the spot being
monitored. The device alarms when temperature exceeds the temperature threshold value.
For temperature measurement, refer to Section 9.4 Temperature Measurement.
VCA function
You can do intelligent analysis, such as perimeter protection. Multiple rules can be
configured for different requirements.
For VCA function, refer to section 9.3 VCA Configuration.
Alarm Input and Output
Refer to the figure below to configure the alarm devices and sensors.
Alarm Device /Alarm
Sensor?
Start
Alarm Device
(e.g., siren)
Alarm Sensor (e.g.,
gas detector)
Connect to Alarm Output
Terminal (labeled ALARM OUT)
END
Connect your camera with the alarm device(s).
Connect to Alarm Input
Terminal (labeled ALARM IN)
Turn on the Camera. Turn on the Camera.
Go to Event>Basic Event>Alarm Output
and set the alarm.
Go to Event>Basic Event>Alarm Input
and set the alarm.
Set the schedule for the alarm device. Set the schedule for the sensor.
Link the alarm to e-mail,
center, alarm out , etc.
Set Alarm Linkage for events.