6. Verify the location of the broken wire.
a. Move the Transmitter to the other end of the wire.
b. Trace from the opposite end of the wire to the location the signal stopped in the
previous step.
Note
The Receiver may not detect a break in a wire in a high-resistance break which is a
partially-open circuit. A high-resistance break stops the flow of higher-level currents
but still conducts the signal through the break. Until the break in the wire is completely
open, the Receiver may not detect the location of the broken wire.
Find a Short in a Circuit
When wires in a circuit touch, they cause a short in the circuit which causes the breaker or fuse
to trip or turn off.
To correct a short in a circuit:
1. Disconnect the wires.
2. Isolate the ends of the wire on both sides of the cable so that they do not touch each other
or other wires or loads.
To find the location of a short in a circuit:
1. Disconnect the wires.
2. Connect the Transmitter to the ground wire on the same circuit as the hot wire. See
Figure 19.
Note
The signal may be weak and difficult to detect due to the cancellation effect. See
Connect the Transmitter.