Note
You should set the face recognion terminal's Wiegand direcon as Input to connect to a
Wiegand card reader. If connects to an access controller, you should set the Wiegand direcon as
Output to transmit authencaon informaon to the access controller.
For details about Wiegand direcon sengs, see Set Wiegand Parameters .
Do not wire the device to the electric supply directly.
4.3 Wire Secure Door Control Unit
You can connect the terminal with the secure door control unit.
The wiring diagram is as follows.
Figure 4-2 Secure Door Control Unit Wiring
Note
The secure door control unit should connect to an external power supply separately. The suggested
external power supply is 12V, 0.5A.
4.4 Wire Fire Module
4.4.1 Wiring Diagram of Door Open When Powering O
Lock Type: Anode Lock, Magnec Lock, and Electric Bolt (NO)
Security Type: Door Open When Powering O
Scenario: Installed in Fire Engine Access