User Manual Winix AM80 True HEPA Air Purifier with Washable Advanced Odor Control (AOC) Carbon Filter, 360sq ft Room Capacity

Documents for Winix AM80

The following documents are available:
User Manual Specification Photos
AM80 photo
1
4
2
5
3
6
PACKAGE CONTENTS
FRONT BACK
Control Panel
Front Panel
Air Outlet
Vent
Handle
Power Plug
(1) In front of Pre-Filter
(1) AOC™ Carbon Filter
(1) True HEPA Filter
Unit User Manual
AM80
The product warranty is printed on the back of this guide.
This product is manufactured for use only in USA / CA.
This product is suitable for 120 V only.
WHERE TO USE
MODEL PART DIAGRAM
12~18 in
12~18 in
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause
product malfunction.
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow 12 ~ 18 in. from walls for maximum air flow
01. Auto Mode
The LED "Auto" light will indicate when Auto Mode is
activated.
When in Auto Mode, the Fan Speed is automatically
adjusted according to the indoor air quality.
As the indoor air quality improves, the fan speed
will automatically be decreased. If the indoor air
quality worsens, the fan speed will automatically
increase.
02. Air Quality Indicator
Color coded LED indicates one of three levels of air quality.
The three levels of air quality are:
BLUE (good), AMBER (fair), RED (poor).
03. Fan Speed
Indicates the current fan speed.
04. PlasmaWave
®
Indicator
Indicates whether PlasmaWave
®
is enabled or
disabled.
CONTROL PANEL
05. Sleep Mode
The LED "Sleep" light will indicate when Sleep Mode is
activated.
When Sleep Mode is activated, the Air Quality
Indicator LED light is disabled.
When Sleep Mode is activated, the fan speed is
automatically set to quiet.
06. Check Filter
LED light indicates when it is time to change the filter.
07. Filter Reset Button
After replacing the True HEPA Filter, use a small object such
as a paper clip, to press and hold the Reset Button for at
least 5 seconds until the Check Filter light turns off.
08. Smart Sensor
When in Auto Mode, the Smart Sensor detects the
amount of impurities in the environment to adjust
fan speeds.
09. Power Button
Turns the unit on or off. During the first 30 seconds
of powering up, the Air Quality Indicator will cycle
through Blue, Amber and Red colors.
Smart Sensor takes approximately 4minutes to
gauge the air quality in the environment before
normal operation begins.
10. Fan Speed/Auto/Sleep Buttons
Use the Fan Speed arrow buttons to set the desired
fan speed. Fan Speeds cycle over in this sequence:
Auto, Low, Medium, High, Turbo, Sleep, Auto.
11. PlasmaWave
®
Button
Press the Plasmawave
®
Button when the unit is on to
enable or disable this feature. By default, PlasmaWave
®
is enabled whenever the unit is powered on.
When the unit is running, you may hear a chirping
or buzzing sound. The sound is from large particles
passing through PlasmaWave
®
, it is normal and does
not signify product failure.
12. Light Sensor
Detects the amount of ambient light in the
environment. When in Auto Mode, the Light Sensor
detects when to put the unit into Sleep Mode.
When to Replace Filters
Filter Indicator Light When to Service When to Replace
Pre-Filter
none Clean once every 14 days Permanent
Advanced Odor Control™
Carbon Filter
none
Can NOT be WASHED Lasts Approx. 12 months
True HEPA Filter
When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter.
Intervals between filter replacement may vary depending on environment.
MAINTENANCE
3
True HEPA Filter
2
Advanced Odor Control™
Carbon Filter
4
PlasmaWave®Pre-Filter
1
4-STAGE AIR PURIFICATION
01. Pre-Filter
Designed to catch larger airborne particles found
indoors.
03. True HEPA Filter
Captures 99.97%* of airborne allergens including; pollen,
mold spores, dust, pet dander, microbes, and smoke
(*particles as small as 0.3 microns in size.)
02. Advanced Odor Control™ Carbon Filter
Reduces VOCs and household odors from cooking,
pets, and smoke.
04. PlasmaWave
®
PlamaWave
®
creates Hydroxyls which can help to
reduce the presence of airborne Bacteria, Viruses*
(* Based on independent
laboratory test conducted on
Influenza A Virus H3N2, E. coli, Pseudomonas aeruginosa,
Staphylococcus aureus, Salmonella typhimurium.)
INITIAL OPERATION
Latch
1.
Remove the front panel by grasping its upper
edge and gently pulling forward.
2.
Remove the Pre-Filter, then the bag of filters
behind it.
3.
Remove filters from protective plastic wrap.
4.
Install the filters until they fit securely in place.
03. True HEPA Filter (back)
02. Advanced Odor Control™ Carbon Filter (middle)
01. Pre-Filter (front)
Latch
5.
After filters are installed, close the front panel.
6.
Insert the power cord into an electrical outlet.
After replacing a filter,
press the RESET button
for at least 5 seconds.
REPLACING FILTERS
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean
the Pre-Filter.
If it is excessively soiled, rinse in room temperature
water.
Do not use detergent or soap.
Allow the filter to dry for 24 hours or more before using.
Intervals between filter cleaning may vary
depending on the air quality.
Do not use hot water
over 104
o
F or volatile fluids such as paint thinner.
NOTICE
Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room temperature
water.
Afterwards, wipe it down with a clean, dry cloth.
Open the front panel and clean the interior with a
vacuum cleaner.
For optimal performance, clean every 1-2 months.
NOTICE
When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
Never disassemble, repair, or modify this unit yourself.
Do not use flammable sprays or liquid detergents.
Do not allow children to clean or maintain the unit.
Before cleaning or maintaining, ensure unit is unplugged.
AM80_QG_EN.indd 1
AM80_QG_EN.indd 1
2020-10-22 오후 5:16:42
2020-10-22 오후 5:16:42
Loading ...

Specifications