GE - General Electric JGBP32SEN2SS GE gas range

User Manual - Page 45

For JGBP32SEN2SS.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation Instructions
I-_ INSTALLING THE ANTI-TIP
DEVICE
-&WARNING!
If the Anti-Tip Device supplied with the range
does not fit this application, use the Anti-Tip
Device X_B02k 10020.
Range must be secured with an approved Anti-Tip
device.
Unless properly installed, the range could be
tipped by you or a child standing, sitting or
leaning on an open dooL
After installing the Anti-Tip device, verify that
it is in place by carefl_lly attempting to tilt the
range forward.
This range has been designed to meet all
recognized industry tip standards for all normal
conditions.
The use of this device does not preclude tipping
of the range when not properly installed.
A. Mark file wall where file RIGHT EDGE of file xange
is m be locamd. Be sure m allow for the counmrtop
overhang if you intend to install file x_mge next to
cabinets.
Slotted head
screw
Approx.20c
Anti-Tip [
device [
!
Wallplate I
I
Marked edge
2W' ,. of range
/
B. I,ocate the outside edge of the device 2_" toward
the center of the range fiom the marked edge of
the range.
C. Using the device as a template, mark the position of
the hole for the screw.
D. Fox wood construction, chill a pilot hole at an angle
of 20 degrees flom the hoxizontal. A nail or awl
may be used if a chill is not available.
Mount the And-Tip device with the screw provided.
Fox cement or concrete construction, you will need
a 1/4" x 1½" lag bolt and a 1/2" O.D. sleeve anchox;
which are not provided. Drill the recommended size
hole for the hardware.
INSTALLING THE ANTI-TIP
DEVICE (CONT.)
Wallboard
Wood screw
Back of range
Install the sleeve anchor into the drilled hole and then
install the lag bolt through the device. The bolts I_Qtlst be
properly tightened as recommended for the hardware.
E. Slide the range against die wall, and check for proper
installation by grasping the flont edge of the cookmp
and carefillly atmmpfing m flit the range foxavard. The
bracket should stop the range within 4 inches. If it
does not, the bracket must be reinstalled.
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls are left in the off position. Make
sure the flow of combustion and ventilation air to the
range is unobstructed.
CONVERTING TO LP GAS (or
converting back to natural gas from LP)
This range leaves the factory set for use with natural gas.
If you want to convert to LP gas, the conversion must be
performed by a qualified LP gas installer.
The convexMon instructions and IP orifices can be found
attached to the range next to the pressure regulatoL
Keep these instructions and the orifices in case you want
to convert back to nattm_l gas.
45