6.3 Functions
Temperature
The temperature depends on the following factors:
-
the number of times the door is opened
-
The duration the door is opened
-
the room temperature of the installation location
-
the type, temperature and amount of food
Freezer compartment Recommended setting
0 °F (-18 °C)
Setting the temperature
Fig. 7
u
Set the value. (see 6.2 Operating logic) .
w
The set temperature is shown on the bottom right of the
display.
SuperFrost
Select this function for the maximum freezing setting, to
reach lower freezing temperatures.
Use:
-
To freeze more than 4.41 lbs (2 kg) fresh food a day.
-
Freezing fresh food quickly to the core.
-
Increasing the cold reserves in the stored goods before
defrosting the appliance.
Activating/deactivating settings
With a small volume of frozen goods:
u
Activate 6 hours before use.
With the maximum volume of frozen goods:
u
Activate 24 hours before use.
u
Activating/deactivating (see 6.2 Operating logic) .
-or-
u
Activate/deactivate in the Liebherr SmartDevice-App.
The function automatically turns off. The appliance goes
back to normal mode. The temperature adjusts itself to
the set level.
PartyMode
This option offers an assortment of special functions and
settings that are useful if you are having a party.
The following functions are activated:
-
SuperFrost
-
IceMaker
and
MaxIce
You can set any functions you like. Your changes are lost
when the option is switched off.
Activating/deactivating settings
u
Activating/deactivating (see 6.2 Operating logic) .
w
On: All functions are activated at the same time.
w
Deactivated: Previously set temperatures are restored.
The function is automatically switched off after 24 hours.
EnergySaver
This function reduces energy consumption. If you activate
this function, the cooling temperature increases.
Temperature
zone
Recommended
setting
Temperature when
EnergySaver acti-
vated
0 °F (-18 °C) 4 °F (-16 °C)
Use:
-
Save energy.
Activating/deactivating settings
u
Activating/deactivating (see 6.2 Operating logic) .
w
Activated: Higher temperatures are set in all tempera-
ture zones.
w
Deactivated: Previously set temperatures are restored.
IceMaker / MaxIce
This function activates the production of ice cubes.
Use:
-
If this function is activated, you can decide between the
normal IceMaker function and MaxIce.
-
The MaxIce makes approx. 1.5 kg of ice cubes per 24 h
within a short time.
The ice cube size can be set with the ice cube size func-
tion. (see Ice cubes)
The lines can be cleaned with the TubeClean function.
(see TubeClean)
Activating the function
Make sure that the following requirements are fulfilled:
q
The water supply is established at the fixed water
connection. See Assembly Manual.
q
IceMaker is put into operation. (see 7.3 IceMaker)
Use
* Depending on model and options 11