Hoshizaki KM301BAJ KM-301BAJ 30" Undercounter Air Cooled Ice Machine with 290 lbs. Daily Ice Production, 100 lbs. Storage Capacity and EverCheck Alert System in Stainless Steel

Instruction Manual - Page 17

For KM301BAJ.

PDF File Manual, 29 pages, Read Online | Download pdf file

KM301BAJ photo
Loading ...
Loading ...
Loading ...
Icemaker Water Supply
Inlet 1/2" FPT
Icemaker Drain
Outlet 3/4" FPT
Fig. 6
KM-301BWJ
Condenser Return
Outlet 1/2" FPT
Condenser Water
Supply Inlet 1/2" FPT
To approved
oor drain
2" (5 cm)
air gap
Drain
Floor
1/4" fall
per foot
Shut-off Valve
Drain Valve
Minimum 1/4" Nominal ID
Copper Water Tubing or
Equivalent
Shut-off Valve
Drain Valve
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Minimum 1/4" Nominal ID
Copper Water Tubing or
Equivalent
Shut-Off Valve
Drain Valve
Be sure there is sufficient
extra water supply line
and drain line for the
appliance to be pulled out
for service.
Separate piping to
approved drain. Leave a
2" (5 cm) vertical air gap
between the end of each
pipe and the drain.
Vent Tube
b) Connection to a Closed Loop System
Condenser Water
Supply Inlet
Minimum Condenser
Water Supply Line Size
Condenser
Return Outlet
Minimum Condenser
Return Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper
Water Tubing or Equivalent
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper
Water Tubing or Equivalent
Shut-off valves and drain valves must be installed at both the condenser water supply inlet
and condenser return outlet.
• Minimum water ow to the condenser is 4 GPM.
The pressure differential between the condenser water supply inlet and condenser return
outlet must be no less than 10 PSIG.
When using a glycol blend, the solution mixture should be less than 30% glycol.
In order to maintain the proper high side pressure, the condenser water supply inlet
temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation is
complete, conrm the condenser drain outlet temperature 5 minutes after a freeze cycle
starts. If the condenser drain outlet temperature is not in the proper range, use a at
blade screwdriver to rotate the adjustment screw on the water-regulating valve until the
temperature is in the proper range.
17
Loading ...
Loading ...
Loading ...