1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker Water
Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker Drain
Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper Water
Tubing or Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal ID Hard Pipe
or Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 4
KM-231BAJ
KM-301BAJ
Icemaker Water Supply
Inlet 1/2" FPT
Icemaker Drain Outlet
3/4" FPT
Shut-off Valve
To approved
oor drain
2" (5 cm)
air gap
Drain
Floor
Be sure there is sufficient
extra water supply line and
drain line for the appliance to
be pulled out for service.
Separate piping to approved
drain. Leave a 2" (5 cm)
vertical air gap between the
end of each pipe and the
drain.
Drain Valve
1/4" fall per foot
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Minimum 1/4" Nominal ID Copper
Water Tubing or Equivalent
Vent Tube
15