4-3.TESTRUN
• Besuretoperformthetestrunforeachunit.Makesureeachindoorunitoperatesproperlyfollowingtheinstallationmanualattachedtotheunit.
• Ifyouperformthetestrunforallindoorunitsatonce,youcannotdetectanyerroneousconnection,ifany,oftherefrigerantpipesandtheindoor/outdoor
unit connecting wires.
About the restart protective mechanism
Once
the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner.
4-4.EXPLANATIONTOTHEUSER
• UsingtheOPERATINGINSTRUCTIONS,explaintotheuserhowtousetheairconditioner(howtousetheremotecontroller,howtoremovetheairl-
ters,howtoremoveorputtheremotecontrollerintheremotecontrollerholder,howtoclean,precautionsforoperation,etc.)
• RecommendtheusertoreadtheOPERATINGINSTRUCTIONScarefully.
5. RELOCATION AND MAINTENANCE
5-1. PUMPING DOWN
Whenrelocatingordisposingoftheairconditioner,pumpdownthesystemfollowingtheprocedurebelowsothatrefrigerantisnotreleasedintotheatmos-
phere.
1)
Connectthegaugemanifoldvalvetotheserviceportofthestopvalveonthegaspipesideoftheoutdoorunit.
2)Fullyclosethestopvalveontheliquidpipesideoftheoutdoorunit.
3)Closethestopvalveonthegaspipesideoftheoutdoorunitalmostcompletelysothatitcanbeeasilyclosedfullywhenthepressuregaugeshows0psi
[Gauge](0MPa).
4)StarttheemergencyCOOLoperation.
To start the emergencyoperationinCOOLmode,disconnectthepowersupplyplugand/orturnoffthebreaker.After15seconds,connectthepower
supplyplugand/orturnonthebreaker,andthenpresstheE.O.SWonce.(TheemergencyCOOLoperationcanbeperformedcontinuouslyforupto30
minutes.)
5)
Fullyclosethestopvalveonthegaspipesideoftheoutdoorunitwhenthepressuregaugeshows(0.1to0psi[Gauge](0.05to0MPa)).
6)StoptheemergencyCOOLoperation.
To stop operation, press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions for details.
When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes. The compressor may burst if air etc. get into it.
WARNING
JG79A253H04_en.indd 8 2014/03/10 14:12:58