1-6. INSTALLATION DIAGRAM
Unitsshouldbeinstalledbylicensedcontractoraccordingtolocalcoderequirements.
Aftertheleaktest,applyinsulat-
ingmaterialtightlysothatthereis
no gap.
When the piping is to be at-
tached to a wall containing metals
(tinplated)ormetalnetting,usea
chemicallytreatedwoodenpiece
8in.(200mm)orthickerbetween
the wall and the piping or wrap 7
to8turnsofinsulationvinyltape
around the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before removing
the old air conditioner. Remake
areaccordingtothedimension
for new refrigerant.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Powersupplycord* 1
(B) I
ndoor/outdoor unit connecting wire* 1
(C) Extension
pipe(Referto1-4.) 1
(D) W
all hole cover 1
(E) Piping
tape 1
(F)
Extension
drain hose
(orsoftPVChose,19/32in.(15mm)
inner diameter or hard PVC pipe
VP16)
1
(G) Refrigeration
oil
Little
amount
(H) Putty 1
(I) Pipe
xingband 2 to 7
(J) Fixing
screwfor(I) 2 to 7
(K) W
all hole sleeve 1
(L)
Soft
PVChose,19/32in.(15mm)
inner diameter or hard PVC pipe
VP16 for drain socket
1
* Note:
Place
indoor/outdoorunitconnectingwire(B)and
powersupplycord(A)atleast40in.(1m)away
from the TV antenna wire.
The“Q’ty”for(B)to(K)intheabovetableisquan
-
tity
tobeusedperindoorunit.
MXZ-2B20NA
More than 4 in.
(100mm)
Open as a rule
More than 20 in.
(500mm)ifthefrontand
both sides are open
More than
4
in.(100mm)
More than
8
in.(200mm)ifthereare
obstacles to both sides
Open as a rule
Morethan20in.(500mm)iftheback,
both sides and top are open
Morethan14in.(350mm)
1-7. MOUNTING ARRANGEMENT OF DRAIN SOCKET
Pleaseperformthedrainpipingworkonlywhendrainingfromoneplace.
1)Chooseoneholetodischargedrainandinstallthedrainsockettothehole.
2)Closetherestoftheholeswiththedraincaps.
3)Connectavinylhoseof19/32in.(15mm)intheinsidediameteronthemarketwiththedrainsocketandleaddrain.
Note:
Install
theunithorizontally.
Donotusethedrainsocketinthecoldregions.Drainmayfreezeanditmakesthefanstop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unitand/ or the grounds
frombeingwetbydrainwaterordamagedbyfrozendrainwater.
Outdoor unit installation
Air inlet
32 -7/8
Air inlet
13
14 -1/4
15 -5/8
Air outlet
[Unit:mm]
19 -11/16
6 -1/2
2-3/8×13/16Ovalholes
Air inlet
835
Air
inlet
330
361
396
Air outlet
500166
4-10
×21Ovalholes
[Unit:inch]