Mitsubishi MXZ-2B20NA-1 20k BTU - M-Series Outdoor Condenser - For 2 Zones

INSTALLATION INSTRUCTIONS - Page 3

For MXZ-2B20NA-1. Series: M-Series
Also, The document are for others Mitsubishi models: MXZ-2B20NA, MXZ-2B20NA, MXZ-3B24NA, MXZ-3B30NA, MXZ-4B36NA, MXZ-5B42NA

PDF File Manual, 28 pages, Read Online | Download pdf file

MXZ-2B20NA-1 photo
Loading ...
Loading ...
3
2.
Front (blowing) side open
As long as space like the one
showninthegurecanbe
maintained, it does not mat-
ter
if there are obstacles in
three directions (but top side
isopen).
4.
Obstacles on front and rear side only
Theunitcanbeusedbyat-
taching an optional outdoor
blowingguide(MAC-889SG)
(but both sides and top are
open).
1-4.SELECTINGPIPESIZEANDOPTIONALDIFFERENT-DIAMETERJOINTS
Thediameterofconnectionpipesdiffersaccordingtothetypeandcapacityofindoorunits.Matchthediametersofconnectionpipesforindoorandoutdoor
units according to the following table.
If the diameter of connection pipes does not match the diameter of pipe end connections, use optional different-diameter joints.
[inch(mm)]
Outdoor unit
Indoor unit
09 or less/12 15
Pipe
size
(liquid/gas)
1/4(6.35)/3/8(9.52) 1/4(6.35)/1/2(12.7)
A UNIT
1/4(6.35)/3/8(9.52) - / - - / MAC-454JP
B UNIT
FREE SPACE REQUIRED AROUND OUTDOOR UNIT
1-5. SELECTING THE INSTALLATION LOCATION
Where it is not exposed to strong wind.
• Whereairowisgoodanddustless.
Where rain or direct sunshine can be avoided as much as possible.
• Whereneighboursarenotannoyedbyoperationsoundorhotair.
Where rigid wall or support is available to prevent the increase of op
-
eration
sound or vibration.
Where there is no risk of combustible gas leakage.
When installing the unit at a high level, be sure to secure the unit legs.
• Whereitisatleast9.84ft(3m)awayfromtheantennaofTVsetor
radio.OperationoftheairconditionermayinterferewithradioorTVre
-
c
eptioninareaswherereceptionisweak.Anampliermayberequired
for the affected device.
• Installtheunithorizontally.
• Pleaseinstallitinanareanotaffectedbysnowfallorblowingsnow.
Inareaswithheavysnow,pleaseinstallacanopy,apedestaland/or
somebafeboards.
Note:
It is advisable to make a piping loop near outdoor unit so as to reduce
vibration transmitted from there.
Note:
When
operating the air conditioner in low outside temperature, be sure
to follow the instructions described below.
Never install the outdoor unit in a place where its air inlet/outlet side
maybeexposeddirectlytowind.
To prevent exposure to wind, install the outdoor unit with its air inlet
side facing the wall.
To prevent exposure to wind, it is recommended to install a baffle
board on the air outlet side of the outdoor unit.
Avoid the following places for installation where air conditioner trouble
is liable to occur.
• Whereammablegascouldleak.
Where there is much machine oil.
• Saltyplacessuchastheseaside.
• Wheresuldegasisgeneratedsuchasahotspring.
• Wherethereishigh-frequencyorwirelessequipment.
Blowingguide(MAC-889SG)
4in.(100mm)
or more
20in.(500mm)
or more
Service space
When installing the unit in an area that is enclosed on four sides such
asaverandah,besuretoleavemovethan8in.(200mm)behindthe
unit as shown.
• When thereis alack ofairow orthere is a possibility ofbecoming
short cycle, install an outletguide and makesure there is enough
space behind the rear side of the air inlet.
Note:
Make
surenottoinstallseveraloutdoorunitssidewaysnexttoeach
other.
Window
More than 4 in.
(100mm)
Lessthan48in.(1,200mm)ofthefrontsurface
side
1.
Top side obstacles
When there is an obstacle
behindtherearsideonly,itdoes
not matter if there is an obstacle
over the top side as shown in the
gurebelow.
3.
Obstacles on front (blowing) side only
In this case, the rear, both sides
and top should be open.
5.
Service space
Keeptheservicespaceasshowninthegurebelowformainte-
nance.
4in.(100mm)
or more
20in.(500mm)
or more
14in.(350mm)ormore
20in.(500mm)
or more
4in.(100mm)
or more
20in.(500mm)
or more
4in.(100mm)
or more
14in.(350mm)
or more
8in.(200mm)
or more
4in.(100mm)
or more
20in.(500mm)
or more
More than 8 in.
(200mm)
More than 8 in.
(200mm)
More than 14 in.
(350mm)
More than 8 in.
(200mm)
JG79A253H04_en.indd 3 2014/03/10 14:12:55