Broil King BK923614 26 Inch Freestanding Vertical Gas Smoker with 770 sq. in. Total Cooking Space, 4 cu. ft. Capacity, 14,000 BTU Burner, 4 Adjustable Cooking Grids, Sure-Lite Electronic Ignition System, and Adjustable Roto-Draft Damper System

Owner's Manual - Page 4

For BK923614.

PDF File Manual, 36 pages, Read Online | Download pdf file

BK923614 photo
Loading ...
Loading ...
Loading ...
LP GAS CYLINDER
4
QCC
®
-1 QUICK CLOSING COUPLING
1. All models are designed to be used with an LP gas cylinder
equipped with the QCC
®
-1 Quick Closing Coupling system.
2. The QCC
®
-1 system incorporates new safety features required
by the American National Standards Institute (ANSI) and the
Canadian Standards Steering Committee.
Gas will not flow until a positive connection has been made.
A thermal element will shut off the flow of gas between 240° and
300° F.
When activated, a Flow Limiting Device will limit the flow of gas
to 10 cubic feet per hour.
3. The LP Gas Cylinder is not included with the Gas Grill. Be
sure to purchase one with the QCC
®
valve. This valve is
recognized by the external threads on the inlet port of the valve.
QCC
®
equipped cylinders are available from your Gas Grill
Dealer.
NOTE: Any attempt to connect the regulator, by use of adapters
or any other means, to any other valve could result in damage,
fire or injury and may negate the important safety features
designed into the QCC
®
-1 system.
SPECIFICATION:
1. All LP gas cylinders used with this appliance must be
constructed and marked in accordance with the Specifications
for LP Gas Cylinders of the U.S. Department of Transportation
(D.O.T.) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable
2. The LP gas cylinder used for this appliance must not have a
capacity larger than 20 lb.(9 kg). Approximately 18" (46cm) high,
12" (31cm) diameter
3. All LP gas cylinders used with this appliance should be inspected
at every filling and re qualified by a licensed service outlet at the
expiry date (10 years), in accordance with the DOT (USA) and
CTC (Canada) codes for LP Gas Cylinders.
4. All LP gas cylinders used with this appliance must be provided
with a shutoff valve terminating in a cylinder valve outlet No. 510,
specified in the Standard for Compressed Gas Cylinder Valve
Outlet and Inlet Connection (USA) ANSI/CGA-V-1-1977
(Canada) CSA B96.
5. The cylinder supply system must be arranged for vapor
withdrawal.
6. The cylinder must include a collar to protect the cylinder valve.
7. The cylinder must be installed as per assembly instructions.
8. Never fill the cylinder beyond 80% full. A fire causing death or
serious injury may occur.
9. The cylinder valve must include a safety relief device having
direct communication with the vapour space of the cylinder.
HANDLING:
1. Government regulations prohibit shipping full LP gas cylinders.
You must take your new cylinder to a LP gas dealer for filling.
2. A filled LP gas cylinder is under very high pressure. Always
handle carefully and transport in the upright position. Protect
the valve from accidental damage.
3. Do not tip the LP gas cylinder while connecting it to the regulator.
Fasten the cylinder securely during transport, use and storage.
4. If the cylinder is tipped after it is connected to the regulator, shut
off the gas, disconnect the regulator and have it checked before
using again.
STORAGE:
1. Store the LP gas cylinder outdoors in a well ventilated place.
2. Do not store the LP gas cylinder in direct sunlight, near a source
of heat or combustion.
3. If you intend to store the grill indoors, disconnect and remove the
LP gas cylinder first. Disconnected cylinders must have a dust
cap installed and must not be stored in a building, garage or any
other enclosed area.
4. Keep out of the reach of children.
5. When the LP gas cylinder is connected to the gas grill, the gas
grill and LP gas cylinder must be stored outside in a well
ventilated place.
OPERATION:
1. Never connect your gas grill to an LP gas cylinder without the
regulator provided, and NEVER TO AN UNREGULATED LP
GAS SUPPLY. The gas regulator supplied with the appliance
must be used.
2. Always leak test the LP gas cylinder to regulator connection
when connecting the LP gas cylinder to the appliance. See
"Leak Testing".
3. Do not operate appliance if the smell of LP gas is present.
Extinguish all flame and determine source of LP gas before
proceeding. Do not ignite the appliance until the LP gas leak
has been found and sealed.
4. Always shut off LP gas cylinder valve when the appliance is not
in use.
Loading ...
Loading ...
Loading ...