Menu item Description
Pitch
0.08–100 (10*)
Specify the pitch for fixed or monospaced fonts.
Note: Pitch refers to the number of
fixed
‑space characters in a horizontal
inch of type.
Orientation
Portrait*
Landscape
Reverse Portrait*
Reverse Landscape
Specify the orientation of text and graphics on the page.
Lines per Page
1–255
Specify the number of lines of text for each page printed through the PCL®
data stream.
Notes:
• This menu item activates vertical escapement that causes the
selected number of requested lines to print between the default
margins of the page.
• 60 is the U.S. factory default setting. 64 is the international factory
default setting.
PCL5 Minimum Line Width
1–30 (2*)
Set the initial minimum stroke width of any job printed in 1200 dpi.
PCLXL Minimum Line Width
1–30 (2*)
A4 Width
198 mm*
203 mm
Set the width of the logical page on A4‑size paper.
Note: Logical page is the space on the physical page where data is
printed.
Auto CR after LF
O*
On
Set the printer to perform a carriage return after a line feed control
command.
Note: Carriage return is a mechanism that commands the printer to move
the position of the cursor to the first position on the same line.
Auto LF after CR
O*
On
Set the printer to perform a line feed after a carriage return control
command.
Tray Renumber
Assign MP Feeder
Assign Tray [x]
Assign Manual Paper
Assign Manual Envelope
View Factory Defaults
Restore Defaults
• Configure the printer to work with a dierent print driver or custom
application that uses a dierent set of source assignments to request a
given paper source.
• Show the factory default value assigned for each paper source.
• Restore the tray renumber values to their factory defaults.
Print Timeout
O
On* (90 seconds)
Set the printer to end a print job after it has been idle for the specified
amount of time.
Note: An asterisk (*) next to a value indicates the factory default setting.