14
Basic Operation
Control Menu Options
Enable/Disable Alarm
Tap the
button repeatedly to advance the LCD to the icon. Press the button to
select ON or OFF alarm mode settings. The last option displayed before navigating away from
this menu option will be the selected setting.
Note: Disabling the alarm via this control menu option will silence the alarm under all conditions, including
low battery conditions.
LCD Brightness
Tap the
button repeatedly to advance to the LCD brightness screen marked “LCD.” Press
the
button to select Medium Backlight (default), High Backlight or Dim Backlight. The last
option displayed before navigating away from this menu option will be the selected setting.
Note: The default brightness is set at medium. Any time a button is pressed, the LCD will engage the high
brightness setting. After 2 minutes of inactivity, the backlight will revert to the selected setting until a button is
pressed.
Self-test
Tap the
button repeatedly to advance to the TEST BATT display. Press the button to
initiate the test. The test will last approximately 10 seconds as the UPS switches to battery to
test the capacity with a load. Upon completion of the test, the display will indicate PAS or BAD
(pass or bad) for 20 seconds, and then return to the home screen. Connected equipment can
remain on during the test. Do not unplug your UPS to test it; this will remove safe electrical
grounding.
Note: If the self-test result is BAD, it may be due to the batteries not being charged for 24 hours. Fully charge
the batteries and repeat the self-test. Please refer to the note under Step 3 on Page 7.
Scroll Control
This setting is normally set to “OFF.” Setting it to “ON” allows the user to select the option to
automatically scroll each operating condition of the UPS (such as Input Voltage, Output Voltage
and Runtime) automatically.
Tap the
button repeatedly to advance to the Scroll display as shown above.
Press the
button to advance to the next available option. The last option displayed, before
navigating away from this menu option, will be the selected setting.
Notes:
1. Each condition is displayed in 2-second intervals.
2. If a button is pressed while Scroll Mode is enabled, the scroll function will pause for 10 seconds to allow
the user to manually make menu selections.