Loading ...
Loading ...
Loading ...
ATE
Category
Reporting
Time
Protocols Communication Devices
Communication
Device to be Used
PSTN 2G/3G IP
DP3 3 min Encrypted √ √
The two check
marked
communication
devices
DP4 90 s Encrypted √ √
The two check
marked
communication
devices
ATE: Al-arm transmission equipment.
SPx (Single Path): A value that indicates the performance level achieved by a single
communication device, according to the EN 50136–1 standard.
DPx (Double Path): A value that indicates the performance level achieved by a combination of two
communication devices, according to the EN 50136–1 standard.
Reporting time: The reporting time is prescribed based on the standard of each level of
performance. Reporting time is the maximum time available to report when an alarm
transmission device fails. Al-arm transmission devices meet this requirement by regularly
reporting their status through a specic symbolic test function.
Protocols: Indicates the security level of the protocols to be used for the notication of failures.
Standard protocols and voice protocols are encrypted. High security protocols are encrypted with
an AES 128 bit or AES 256 bit encryption key.
Communication devices: Implemented communication devices.
Communication devices to be used: Indicates the number of and which communication devices
are to be used based on the ATE category.
Table 1-3 Technical specication
Technical Specification Description
ACE Classication Type A
Environmental Class II
Supply Voltage 12 VDC, 1.5 A
Product Dimensions 163.0 mm × 163.0 mm × 32.0 mm (6.42" × 6.42" × 1.26")
Packaging Dimensions 219.0 mm × 187.0 mm × 91.0 mm (8.62" × 7.36" × 3.58")
Operating Temperature
–10 °C to +50 °C (+14 °F to +122 °F)
–10 °C to +40 °C (+14 °F to 104 °F) (Certied temperature)
Humidity 10%–90% (RH)
Net Weight 0.38 kg (0.84 lb)
Gross Weight 0.8 kg (1.76 lb)
Casing PC + ABS