20
3.7 RS485 Cable Wiring (Optional)
If you need to connect the RS485A and
RS485B cables, insert the cables through the
bottom Ethernet cable port (L) first. Then
connect the cables to the RS485 port (M) as
specified on the terminal block, respectively.
3.8 Adjusting the Rated Current
The MaxiCharger AC Residential 10 kW/12 kW allow you to manually set a lower maximum current using a
current selector when installing your charger on a circuit rated lower than the maximum rating for your
charger.
1. Remove the covers and locate the current
selector.
2. Use a flathead screwdriver to set the
rotary switch to the appropriate position
per the table below.
3. When the current of your charger is set
lower than the maximum rating, choose
the correct current value from the
Amperage Labels and affix it over the
existing label on the charger.