11
3.3 NEMA Plug-in Outlet
This section introduces how to install a NEMA outlet if you do not have one already.
WARNING
Switch off the circuit breaker of the electrical outlet before installing the charger.
If you already have a NEMA outlet, ensure that it complies with local electrical codes and has a designated
circuit breaker and electrical wiring that are dimensioned appropriately.
IMPORTANT
When installing a NEMA 14-50 outlet, ensure that the ground pin is facing up as shown as per the diagram.
NEMA 14-50P NEMA 6-50P
Ensure you have the correct permits for this electrical installation.
The NEMA outlet must be placed on the left side of the charger.
The power supply cable length is limited to 12” (300 mm).
CAUTION
To reduce the risk of fire, connect only to a circuit with a branch circuit over-current protection of 50 A in
accordance with ANSI/NFPA 70 (US) CSA C22.1 (Canada).