Loading ...
Loading ...
Loading ...
15
find a leak, please do not use the remote control.
If you swallow the battery liquid, rinse your mouth and seek medical attention as soon as possible. The
chemical substances in the battery may burn or cause other health hazards.
SAFETY PROTECTIONS
1. Water-full safety alarm and shut-off protection function
When the water volume exceeds its alarm level in chassis, warning sounds will ring automatically and the water-full icon
will light up on the display. You need to drain the water and restart the unit (for more information about how to drain,
refer to the Drainage Instruction” please). If the unit is not shut down manually, it will return to the original operating
status automatically once the water is fully drained. Or you can connect the power to restart the unit.
2. Anti-frozen protection function
Under COOLING mode, when the compressor continuously runs over 10 minutes and if the tube temperature is 2
/36 for 20 seconds, the anti-frozen protection function will be on, E4 will be shown on LED display, and the
compressor and water wheel motor will stop working, but the upper fan will remain running; if the tube temperature
≥8/46 , the unit will stop anti-frozen protection and return to the original working condition. Compressor will
restart after 3 minutes’ delay for protection.
3. Delay protection function of the compressor
This unit offers re-start protection to compressor. Except that the compressor may start immediately when the unit is
energized first time, there is a 3-minute delay of the re-start protection when the compressor restarts after it stops
running.
4. Coil and room temperature sensor failure:
1) Detect sensor failure at the beginning of power-on or during the power-on state
2) When a sensor failure is detected at the beginning of power-on, it will immediately enter the failure state. If it
returns to normal at this time, it will enter the standby state;
USE THE AIR CONDITIONER
IMPORTANT: If the air conditioner has been tilted on its side, wait 24 hours before turning on the air conditioner to allow
the oil to return to the compressor. This will prevent the air conditioner from failing prematurely.
Hold the handles on side panels to move the unit in upright position.
NOTE:
Do not hold the louver.
Make the unit in the upright position whenever handling or moving it.
Drain the water in the unit completely before handling or moving the unit to prevent water leakage wetting the
floor or carpet.
DRAIN THE INTERNAL WATER
You will need a small pan to catch the water coming out of the water tank. Once the water tank is empty, the unit will
resume operation within a few minutes.
MANUAL DRAINAGE
1. Once the unit shuts down upon water-full, turn off the unit and then unplug.
2. Put the tray below the water outlet at the back of the unit.
3. Unscrew the drain cover, and unplug the water stopper to allow the water flow into the tray.
4. Insert the stopper and screw the drain cover tightly onto the water outlet after drainage.
Loading ...
Loading ...
Loading ...