LIN Trigger and Serial Decode
The following section describes Setup for LIN Signals”, “LIN Trigger and LIN
Serial Decode and includes instructions ontriggering and decoding LIN signals.
Setup for LIN Signals
There are two steps of setting the LIN signal: connecting the signal to oscilloscope
and specifying the parameters of each input signal.
1. Press the Decode key to enter the DECODE function menu.
2. Press the Decode softkey and select the desired slot (Serial 1 or Serial 2).
3. Press Protocol softkey and then select LIN by turning Universal Knob.
4. Press Signal softkey to enter the SIGNAL menu as Figure 50 shows.
Figure 58 LIN SIGNAL Menu
5. Press Source softkey to select the channel that is connected to the LIN signal.
6. Press the Threshold softkey and set the LIN signal’s threshold voltage level by
the Universal Knob. The threshold voltage level is for decoding, and it will be
used as the trigger voltage level when the trigger type is set to serial.
7. Press softkey to return previous menu.
8. Press the Configure softkey to enter the BUS CONFIG menu.
9. Press Baud softkey to set baud rate.
The baud rate can be set as predefined value.
If the desired baud rate is not listed, select custom option, press the
Custom and turn the Universal Knob to set the desired baud rate.