Loading ...
Loading ...
Loading ...
6
GE505 / 54 - GE506 / 56 Models Only.
Electrical supply connection point is located at rear of appliance, approximately 74mm from right
hand side, 501mm from rear and 150mm from floor.
GE508 / 58 Models Only.
Electrical supply connection point is located at rear of appliance, approximately 374mm from right
hand side, 501mm from rear and 150mm from floor.
When connecting this electric appliance to mains supply, ensure that the following is carried out:-
An isolating switch is fitted within 2m of appliance, but not on appliance and in such a position
that user does not have to reach across cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS 3191 part
2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
Branch supply line shall be individually overload protected to correct current rating and supply
chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around wiring entry hole into appliance.
All wiring connections must be tight.
Refer to appropriate wiring standards for size of cable to be supplied to an appliance for current
drawn on that line.
MODEL
1-Phase Connection
1P+N+E
230-240V
3-Phase Connection
3P+N+E
400-415V
GE505
5.5 kW,
22.6 Amps @ 235 V
5.5 kW
L1 - 7.2 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
GE54
5.8 kW,
23.9 Amps @ 235 V
5.8 kW
L1 - 8.5 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
GE506
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE56
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE508
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE58
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.